Skip to main content Link Search Menu Expand Document Warning Info Success Info (external link) Copy Copied Following system colour scheme Selected dark colour scheme Selected light colour scheme Telegram GitHub Edit

The information on this page is taken from the GPON/EPON standard and information from the major vendors of GPON/EPON equipment, each individual item containing a verifiable citation in the standard. Feel free to cite this page as: Quick Start, Hack GPON. Available at: https://hack-gpon.org/quick-start.

Fiber Optic Connectors

Numerous connectors, both standard and proprietary, are used in the field of telecommunication equipment, data lines, television and cable, and other industrial fields.

Some of the common connector
Some of the common connector

The main connector are:

  • Bionic Connector
  • Standard Connector (SC)
  • Ferrule Core Connector (FC)
  • ST Connector (ST)
  • SMA Connector
  • Lucent Connector (LC)
  • Enterprise Systems Connection Connector (ESCON)
  • Fiber Distributed Data Interface Connector (FDDI)
  • Opti-Jack Connector
  • LX-5 Connector
  • Volition Connector
  • MT-RJ Connector
  • MU Connector
  • MT Connector
  • E2000 Connector

Polishing of Fiber Optic Connectors

APC and UPC are different polishing of fiber optic ferrules, and are types of fiber patch cable connectors. Which determine the quality of the fiber optic lightwave transmission, mostly performed in optical return loss and insertion loss1.

Picture of APC and UPC
Picture of APC and UPC

Angled physical connectors are used in the ONT side to reduce back reflections. In case RF signal (1550nm) is introduced there will be two signals traveling in the downstream direction (1490nm + 1550nm), since RF systems are highly sensitive to reflections then the APC connectors reduce the return loss value2.

Next generation systems are planned to operate in over 1500 nm wavelengths, converting APC connectors on the ONT side into planning to the future2.

PON Networks3

  • PON is a kind of passive optical network featuring one-to-multiple-point architecture;
  • PON is short for Passive Optical Network;
  • PON consists of Optical Line Terminal (OLT), Optical Network Unit (ONU) and Passive Optical Splitter.

  • APON: ATM Passive Optical Networks;
  • EPON: Ethernet Passive Optical Networks;
  • GPON: Gigabit-capable Passive Optical Networks;
  • XG(S)-GPON: 10 Gigabit-capable Passive Optical Networks4;

EPON and GPON are complementary and compete against each other in some aspects. So in the following contents, we’d like to make clear the EPON and GPON comparison 5.

Why GPON?

  • GPON is defined by ITU, International Telecomunication Union6.
  • GPON supports Triple - play service, providing competitive all-service solution3.
  • GPON supports high-bandwidth transmission to break down the bandwidth bottleneck of the access over twisted pair cables, so as to satisfy the requirements of high-bandwidth services, such as IPTV and live TV broadcasts3.
  • GPON supports the long-reach (up to 20 km) service coverage to overcome the obstacle of the access technology over twisted pair cables and reduce the network nodes3.
  • With complete standards and high technical requirements, GPON supports integrated services in a good way3.
  • GPON is the choice of large carriers in the international market3.
  • GPON is high broadband efficiency, like 92%3.
  • GPON has integrated QoS handling that makes it better than EPON, because EPON QoS is high cost relative to GPON5.
  • GPON supports splitting up to 1:128, XG(S)-PON up to 1:2565,4.
  • Security: the data transmitted down to ONUs/ONTs are encrypted based on the AES mechanism7.

Why EPON?

  • EPON is defined by IEEE 802.3 standard, ratified as 802.3ah-2004 for 1.25 Gbps (1.0 Gbps prior to 8B/10B coding) and IEEE 802.3av standard for 10Gbps (10G-EPON)8,9.
  • 1/1-EPON supports splitting up to 1:32, 10/*-EPON up to 1:1285,9.
  • In EPON, both downstream and upstream line rates are 1.25 Gbps, but due to the 8B/10B line encoding, the bit rate for data transmission is 1 Gbps10.
  • The use of EPON allows carriers to eliminate complex and expensive ATM and Sonet elements and to simplify their networks, thereby lowering costs to subscribers. Currently, GPON equipment costs are approximately 1.5 to 2 times higher than an EPON10,5.

Layer

Layering model and the associated management services are all mapped over Ethernet (directly or via IP).

  • GPON support the encapsulation of other protocols besides Ethernet, such as ATM11,3,5.
  • XG(S)-PON remove the support of ATM encapsulation7.
  • GPON use two layers of encapsulation are required. First, TDM and Ethernet frames are wrapped into GTC Encapsulation Method (GEM) frames, which have a GFP-like format (derived from Generic Frame Procedure ITU G.7401). Secondly, ATM and GEM frames are both encapsulated into GTC frames that are finally transported over the PON10,5.
  • The main purpose of the GEM frame is to provide a frame-oriented service, as an alternative to ATM, in order to efficiently accommodate Ethernet and TDM frames. With GEM, all traffic is mapped across the GPON network using a variant of SONET/SDH GFP. GEM supports a native transport of voice, video, and data without an added ATM or IP encapsulation layer. That’s why GPON supports downstream rates as high as 2.5 Gbps and upstream rates from 155 Mbps to 2.5 Gbps. It is much faster than EPON10.
  • However, EPON clearly offers a much simpler and more straightforward solution than GPON. The support of ATM and the double encapsulation of GPON serve no real benefit over a pure Ethernet transport scheme10.
  • In EPON, Ethernet frames are carried in their native format on the PON, which greatly simplifies the layering model and the associated management. EPON employs a single layer that uses IP (Internet Protocol) to carry data, voice, and video10,5.
EPON vs GPON Layer
EPON vs GPON Layer

Comunication between ONT and OLT5

  • EPON utilizes IEEE 802.3ah OAM messages for provisioning, fault isolation and performance monitoring in conjunction with SNMP (Simple Network Management Protocol) sets and gets through IETF (Internet Engineering Task Force) and MIBs (Management Information Bases). Additional control messages are MPCP GATEs/REPORTs for bandwidth granting.
  • In GPON there are three different types of control messages: OMCI (ONT Management and Control Interface), OAM, and PLOAM (Physical Layer OAM). Their roles are shown in the table below.
Control channel Format Used for
OMCI Ethernet or ATM Provisioning of ONT service defining layers above the GTC
Embedded OAM Header overhead BW granting, encryption key switching, and DBA
PLOAM ATM Auto discovery and all other PMD and GTC management info. PLOAM messages are directed to ONTs or FF for broadcasts

Wavelength12

PON adopts Wavelength Division Multiplexing (WDM) technology, facilitating bi-direction communication over a single fiber.

To separate upstream/downstream signals of multiple users over a single fibre, PON adopts two multiplexing mechanism:

  • In downstream direction, data packets are transmitted in a broadcast manner;
  • In upstream direction, data packets are transmitted in a TDMA manner.
Fiber Optic Operation Wavelength and Window
Fiber Optic Operation Wavelength and Window
  GPON 1/1-EPON XG(S)-GPON 10/1-EPON 10/10-EPON
Upstream 1310 nm (1260 nm-1360 nm) 1310 nm (1260 nm-1360 nm) 1270 nm (1260 nm-1280 nm) 1310 nm (1260 nm-1360 nm) 1270 nm (1260 nm-1280 nm)
Downstream 1490 nm (1480 nm-1500 nm) 1490 nm (1480 nm-1500 nm) 1577.5 nm (1575 nm-1580 nm) 1577.5 nm (1575 nm-1580 nm) 1577.5 nm (1575 nm-1580 nm)
RF-Overlay 1550 nm (1550 nm-1560 nm) 1550 nm (1550 nm-1560 nm) 1550 nm (1550 nm-1560 nm) 1550 nm (1550 nm-1560 nm) 1550 nm (1550 nm-1560 nm)

Power Budget2,11

  • Splitter attenuation
Splitter Type Attenuation
1:2 ≤ 3.5 dB
1:4 ≤ 7.0 dB
1:8 ≤ 10.5 dB
1:16 ≤ 14.0 dB
1:32 ≤ 17.5 dB
1:64 ≤ 20.5 dB
1:128 ≤ 24.0 dB
  • Loop attenuation: ≤ 0.5 dB (Per Km)

  • Connector attenuation: ≤ 0.3 dB (Per Connector)

Classes for laser11

  Class A Class B Class B+ Class C
Minimum loss 5 dB 10 dB 13 dB 15 dB
Maximun loss 20 dB 25 dB 28 dB 30 dB

The requirements of a particular class may be more stringent for one system type than for another.


  1. Fiber SFP Module Compatibility with APC, UPC, PC https://www.wolonte.com/news.asp?id=599 

  2. GPON E2E Fundamentals, Zyxel 2018  2 3

  3. GPON Fundamentals, Huawei 2010 http://jm.telecoms.free.fr/QCM_Fibre/GPON-Fundamentals_Huawei.pdf  2 3 4 5 6 7 8

  4. G.987.1: 10-Gigabit-capable passive optical networks (XG-PON): General requirements https://www.itu.int/rec/T-REC-G.987.1  2

  5. Comparison of EPON and GPON https://community.fs.com/blog/comparison-of-epon-and-gpon.html  2 3 4 5 6 7 8 9

  6. G.984.1: Gigabit-capable passive optical networks (GPON): General characteristics https://www.itu.int/rec/T-REC-G.984.1 

  7. Fifty Years of Fixed Optical Networks Evolution: A Survey of Architectural and Technological Developments in a Layered Approach https://doi.org/10.3390/telecom3040035  2

  8. IEEE 802.3ah-2004: IEEE Standard for Information technology– Local and metropolitan area networks– Part 3: CSMA/CD Access Method and Physical Layer Specifications Amendment: Media Access Control Parameters, Physical Layers, and Management Parameters for Subscriber Access Networks https://standards.ieee.org/ieee/802.3ah/3179/ 

  9. IEEE 802.3av-2009: IEEE Standard for Information technology– Local and metropolitan area networks– Specific requirements– Part 3: CSMA/CD Access Method and Physical Layer Specifications Amendment 1: Physical Layer Specifications and Management Parameters for 10 Gb/s Passive Optical Networks https://standards.ieee.org/ieee/802.3av/4060/  2

  10. HTFuture: EPON vs GPON Standard https://medium.com/@ivyhtfuture/epon-vs-gpon-standard-b8ec20c55bb3  2 3 4 5 6

  11. Understand GPON Technology https://www.cisco.com/c/en/us/support/docs/switches/catalyst-pon-series/216230-understand-gpon-technology.html  2 3

  12. GPON Principle—Data Multiplexing https://forum.huawei.com/enterprise/en/gpon-principle-data-multiplexing/thread/458243-100181